Hi this is Team Merchant Navy Decoded !!!

Please fill the below form with your query and we will get back to you in next 12 hours.

Rest assured your data is safe with us !!!🙂

Ask Your Query

Piping Systems Onboard Ship

If you were to open up a ship you would find that there is a lot of pipework onboard. There will be pipework for seawater for cooling, fresh water for drinking, fuel for the engine, oil for bearings, steam for heaters, air for starting valves, bilge water to exit the ship, ballast water in and out. There will be miles of piping in the tanks, on the decks, in the engine room and within the accommodation. Usually in hot, damp areas with vibrations and not easy to access.

As piping systems are very important engineers will become familiar with understanding and maintaining them. Leaks at flanges or stuck valves can cause the system to fail causing flooding or fires. This article will explain the main piping systems onboard, what they are made of, how they are joined, how the valves operate and how they can be maintained.

Piping Systems Onboard Ship

Piping Systems

A piping system consists of piping, fittings, valves and supporting structure to allow the fluid to move from one place to another. All piping systems will have a source (Tank, Pump, Seawater), piping and valves. Most systems will have pumps to move the fluid, strainers/filters to keep the fluid clean and valves to control the flow. All systems will have a piping diagram showing where piping, valves, pumps and tanks are located. Understanding piping diagrams and knowing how they relate to actual piping is an important skill. If there are any differences between the piping diagram and the ship you should report this and ensure it is updated.

Understanding piping systems onboard ships is important for marine engineers. Along with studying piping diagrams, engineers should also learn how different shipboard systems operate in real conditions.

The Merchant Navy Decoded App provides access to MND FLIX, where marine engineers can explore practical learning resources related to shipboard machinery and systems.

Main Piping Systems

  • Seawater Systems

    – Water is taken from the sea chests and sea suction valves to go into the coolers. The seawater will go into the coolers, condensers (some configurations), firemain and sanitary services. It will then exit the ship through the discharge valves. As seawater is corrosive and has marine growth the piping should be made from good quality materials and kept clean and inspected regularly.

Seawater Systems

  • Freshwater Systems – There are several different freshwater systems. Cooling water will circulate around the engine and coolers. Domestic water will be used for drinking, washing and cooking. This is often done through a hydrophore tank and is treated. Boiler feed water is also treated.
  • Fuel Oil System – Fuel is transferred from bunker tanks to the engine through the transfer, settling, purifier and service stage. Leak off and return lines are also included. (See fuel system post). Fuel piping will be heated and insulated if required. High pressure piping will be protected. Quick closing valves are installed on the tanks.

Fuel Oil System

  • Lube Oil System – Oil is transported from the sump or drain tank to the bearings and other points via pumps, coolers and filters. This is one of the most important systems as if oil stops flowing to the engine damage can occur quickly.
  • Bilge System – Water is collected from the bilges and machinery spaces to go to the oily water separator. From here it will be discharged overboard or to a holding tank. Valves are installed to prevent cross connecting between the bilges and sea.
  • Ballast System – Ballast tanks are filled and emptied with seawater. Ballast piping runs through large areas of the ship. The valves are often operated remotely from a control station.

Ballast System

  • Fire Main & Fire Fighting Systems – The fire main is used to take seawater from the fire pumps and emergency fire pump to the hydrants and hoses across the ship. Other fixed firefighting systems (Sprinklers, Foam, Watermist & CO2) have their own piping. All of these are very important and must always be ready.
  • Steam & Condensate System – Steam from the boilers will go to the fuel heaters, tank heating coils and accommodation heating. Condensate will return to the feed system. Steam piping will be hot and insulated. Risk of scalding and expansion.
  • Air System – Start, control and service air piping from the compressors and receivers to the engines, valves and outlets. 

Air System

  • Hydraulic System – Hydraulic oil is transported to the steering gear, deck equipment and hatch covers. (See hydraulic valves and pumps posts)
  • Sounding, Vent & Overflow – All tanks will have a sounding pipe to indicate how much is in the tank. An air vent to allow filling and emptying. An overflow to prevent overfilling. Piping is controlled to prevent flooding, fires and pollution.
  • Sanitary & Drainage – Black water (sewage) and Grey water (sinks/showers) will be taken to the sewage treatment plant or overboard. Deck and scupper drainage.

Table of Contents

Materials

Materials will depend on the fluid, pressure, temperature and environment.

  • Carbon steel is often used for fuel, lube oil, steam and air. It is strong and cheap but will corrode. Therefore it will be painted/coated. Often water lines are galvanised.
  • Galvanised steel is used for some water and air lines. It has a zinc coating.
  • Copper and Copper Nickel are resistant to seawater corrosion so often used for seawater cooling and small piping.
  • Stainless steel is used when corrosion resistance and cleanliness are needed. E.g. chemical lines and some freshwater.
  • Plastic and GRP (fibreglass) are resistant to corrosion and are light. Used for ballast and some seawater. They have limitations due to fire performance.
  • Flexible hoses are used when there is movement/vibrations. E.g. hydraulic and some engine connections. Have a limited life span and working pressure. Will be changed at scheduled intervals.

Always use the correct material when repairing as incorrect materials can corrode quickly or burst under pressure.

Joints

  1. Welded – Strong and watertight. Used for most high pressure piping. Welded by qualified welders using approved methods.
  2. Flanged – Connected together with a gasket using bolts. Can be opened for maintenance. Used on valves, pumps and equipment. Must use the correct gasket depending on the fluid, pressure and temperature. Bolts must be tightened evenly and in the correct order.
  3. Threaded – Used on small piping. Sealant or tape is used.
  4. Couplings/Compression – Some piping is connected without welding. Used on small piping and some seawater. Are only approved for certain services as they can fail in a fire.
  5. Expansion Joints/Bellows – Allow expansion due to heat, vibrations and flexing of the ship.

Valves

Valves control the piping systems. The main types are:-

  • Gate – Fully open or closed. Allows a straight flow. Used for isolation.
  • Globe – Controls flow and has a tight seal. Good for throttling.
  • Ball – Quarter turn to open/close. Commonly used on small piping. Quick isolation.
  • Butterfly – Quarter turn disc. Light and compact. Used on large piping. E.g. Seawater and ballast.
  • Non Return (Check) – Only allows flow in one direction. Prevents backflow. Used on seawater discharges to prevent sea flooding.
  • Screw Down Non Return – A combination of check valve and screw to force the valve to close. Used on seawater inlet and discharge.
  • Quick Closing – Can be closed remotely from outside the area in an emergency. Installed on fuel and lube oil tanks.
  • Relief/Safety – Opens to a set pressure to protect piping and equipment.
  • Remote Valves (Hydraulic/Pneumatic/Electric) – Used on ballast, bilge and tank valves. Operated from a control room.

Valves should be labelled. It should be clear whether the valve is open or closed. Valves that won’t close/open are a common issue. Valves should be exercised and overhauled at scheduled intervals.

Strainers/Filters

Strainers are used to protect pumps and equipment. A seawater strainer will prevent weed, shells and rubbish getting into the pump and coolers. Should be cleaned regularly to prevent reduced flow due to blockages. This can cause pumps to run dry or engines to overheat.

Supports/Lagging/Tracing

Piping is supported and hung to allow movement but not too much vibration. If there are no supports or they are loose the piping can crack due to vibration. Lagging is used on hot lines to reduce heat loss. This also prevents people and equipment from burning. On fuel lines it helps keep the fuel at the right temperature. Tracing (steam or electric) is used to keep heavy fuel and some other fluids warm. Lagging should be in good condition. Oil in the lagging is a fire risk so wet/oily lagging should be replaced.

Identification

Piping is colour coded with arrows indicating flow. Labels will indicate what the piping is for.

  • Red – Fire fighting and protection. (Fire main, CO2)
  • Green – Sea water. (Cooling, Ballast)
  • Blue (Light Blue) – Fresh water / Potable
  • Brown – Fuel oil. (Heavy fuel oil, Diesel oil, Bunkers)
  • Yellow – Lubricating oil or flammable gases. (Depending on secondary ring/stripe)
  • Orange – Oils other than fuel. (E.g. Hydraulic oil)
  • White – Compressed air.
  • Silver / Gray – Steam.
  • Black – Waste media, Bilge or Sewage.
  • Violet: Acids and alkalis
  • Maroon – Wet and dry masses.

Always check the labels and diagrams before opening any piping. Don’t rely solely on colours.

Corrosion/Erosion

The harsh conditions onboard mean there are several ways the piping can corrode.

  1. General Corrosion – Mainly external corrosion on steel piping due to salt and moisture.
  2. Pitting & Crevassing – Small holes created quickly.
  3. Galvanic – Different metals in contact in seawater.
  4. Erosion Corrosion – Bends, valves and end of tubes. Fast flowing water causes erosion.
  5. Microbiological & Fouling – Due to marine growth in seawater.

Protection can be done using coatings, anodes, correct materials, good design to ensure good flow and chemical treatments. Wall thickness is often measured using ultrasonic gauges on important lines to see if there is any thinning.

Testing/Maintenance

  • Pressure Testing – New or repaired piping is pressure tested (Usually hydraulically) to a pressure above working pressure. This ensures no leaks and that the piping is strong enough. Pressure and method will be detailed in rules and standards.
  • Flush – New or repaired piping should be flushed to remove any debris. Especially hydraulic and lube oil.
  • Check – Check regularly for leaks, corrosion, damaged lagging, loose supports and worn flexible hoses.
  • Valves – Valves should be exercised, greased and overhauled at scheduled intervals. Check valve sealing and spindle.
  • Scheduled – Flexible hoses, gaskets and sections of piping should be changed at scheduled intervals or if found to be worn.

Safety

Piping is important for fire and flooding. Many things are dictated by rules;

  • High pressure fuel lines are protected and have leak alarms.
  • Quick closing valves on fuel and oil tanks. Operated from outside the engine room.
  • Non return valves on seawater discharges and inlets. Should be easily accessible and in good condition.
  • Important valves can be operated remotely. Indicators show valve position.
  • Systems are isolated to prevent mixing of fuels, freshwater and ballast.
  • Tank vents and overflows prevent overfilling, flooding and fires.
  • Fire resistant materials are used where plastic and non steel piping are used in critical areas.

This will depend on the type and class of ship. Check current SOLAS and class rules.

Safe Piping Practice

Before opening any piping, valve or flange:-

  1. Identify what system and fluid you are dealing with by checking the label and diagram.
  2. Ensure you have authorisation/permission.
  3. Isolate the section of piping. Close the valves on either side and lock/tag.
  4. Depressure and drain the line. Allow hot lines to cool. Steam and hot oil can cause serious burns.
  5. Check for pressure build up.
  6. Wear correct PPE and have spill and fire precautions in place.
  7. After you have finished new gaskets should be used. Tighten flange bolts evenly. Check for leaks. Don’t remove tags until finished and checked.
  8. Never work on any piping unless you have proved it is isolated and depressured.
Common Issues
  • Leaking flanges/gaskets – Incorrect tightening, incorrect gaskets and vibrations.
  • Corrosion/Thinning – Especially seawater and bends.
  • Blockages – Debris, marine growth and scaling in strainers.
  • Valve issues – Stuck, leaking and broken spindle.
  • Water hammer – Caused by sudden closure of valves or air in line. Can cause damage to piping.
  • Vibration and Fatigue cracking – Caused by loose/no supports.
  • Thermal expansion – Hot lines with poor supports.
  • Oily/Damaged lagging – Fire risk.
  • Incorrectly aligned valves – Diverts fluid and causes pressure loss.
  • Cross contamination.

Best Practice

  • Be able to read piping diagrams. Compare to actual piping and valves.
  • Piping and valves should be clearly labelled.
  • Do regular rounds to check for leaks, corrosion, dripping and damaged lagging. Fix any minor issues.
  • Open/close valves slowly to prevent water hammer.
  • Clean strainers at scheduled intervals. Monitor pressure drop.
  • Measure wall thickness on important lines. Keep records.
  • Use correct materials, gaskets and bolts. Tighten flange in correct order.
  • Change flexible hoses at scheduled intervals. Don’t use past rated life.
  • Exercise valves.
  • Report any differences between diagrams. Update when changes are made to piping.

Conclusion

Piping systems onboard a ship act like the blood stream of the ship. Each service (Seawater, Fuel, Steam, Air etc.) will have its own piping, valves and equipment. Knowing what each service carries, how it is joined, what valves are used, how it can fail and how to safely isolate will help you identify any leaks quicker, prevent costly mistakes and keep the ships systems running.

Frequently Asked Questions (FAQs)

Seawater, Freshwater, Fuel Oil, Lube Oil, Bilge, Ballast, Firemain, Steam & Condensate, Air, Hydraulic, Sounding, Vent & Overflow, Sanitary & Drainage.

Carbon steel, Galvanised steel, copper nickel, Stainless steel, Plastic, GRP and Flexible hoses. Depending on what fluid is flowing, pressure, temperature and rules.

Gate Valve – Fully open or closed. Straight flow. For isolation.

Globe Valve – Better for controlling flow. Tight seal.

Prevent seawater from coming back into the ship.

Can be closed remotely from outside the area. Used in emergencies. E.g. Valves on fuel tanks during a fire.

To reduce heat loss, keep fuel/other fluids at correct temperature and prevent people from burning.

Sudden stoppage of liquid flow. E.g. Too quick closing of valves or air in line.

Can cause damage to piping.

Using ultrasonic thickness gauges on important lines. This will identify any thinning due to corrosion/erosion.

Identify what system you are dealing with. Ensure you have permission. Isolate. Lock/tag. Depressure and drain. Check for pressure build up. Wear correct PPE.

There is no universal colour coding on all ships. Always check the label and diagram.

Disclaimer :- The opinions expressed in this article belong solely to the author and may not necessarily reflect those of Merchant Navy Decoded. We cannot guarantee the accuracy of the information provided and disclaim any responsibility for it. Data and visuals used are sourced from publicly available information and may not be authenticated by any regulatory body. Reviews and comments appearing on our blogs represent the opinions of individuals and do not necessarily reflect the views of Merchant Navy Decoded. We are not responsible for any loss or damage resulting from reliance on these reviews or comments.

Reproduction, copying, sharing, or use of the article or images in any form is strictly prohibited without prior permission from both the author and Merchant Navy Decoded.

DIWALI SALE

Decoded Discount Alert! up to 50% OFF

DIWALI SALE

Decoded Discount Alert! up to 50% OFF

Use Coupon Code Deep50

Days
Hours
Seconds
0
Would love your thoughts, please comment.x
()
x