Hydraulic Valves Onboard

When on deck there are a lot of things that use hydraulic oil. Hatch covers, deck cranes, mooring winches/windlasses, steerable gear, watertight doors, stern ramps etc. They all use pumps to create pressure, cylinders and motors to do the work and hydraulic valves to direct oil, control how much and at what pressure.

The valves are the brain of the system and knowing what the main types are will help you understand what everything means on a hydraulic circuit diagram.

Hydraulic Valve

Hydraulic Valves Onboard

It can be used to control the oil in three different ways. Directional, pressure or flow.

  • Directional control valves – Directs the oil to go in the right direction to move the cylinder/motor.
  • Pressure control valves – Limit or control the pressure from the pump. Examples would be relief valves, reducing valves and sequence valves.
  • Flow control valves – Control how much oil is going through to move the actuator at the right speed.

There are also check and counterbalance valves. They are based on the same principles but have specific functions.

  1. Directional Control Valves: Directional control valves control the actuator by directing oil. They can start, stop and reverse. The most common type is a spool valve. A spool is a cylinder with grooves that slides in a bore of the valve body. By moving the spool, the grooves align with the correct port.

        Ports are commonly labelled as follows:-

  • P = Pressure supply from pump.
  • T (or R) for tank (the return to the reservoir)
  • A & B = Work ports connecting to either side of a cylinder/motor.

For example a double acting cylinder like a hatch opener. When the spool is in one position P is directed to A and B to T. This will cause oil to flow to one side of the cylinder and drain from the other, causing extension. When the spool is moved to the other position P will go to B and A to T, causing retraction. In the centre position the ports will be blocked or have a specific connection depending on the valve design.

Directional Control Valves

Learn More with the Merchant Navy Decoded App

Want to improve your practical marine engineering knowledge? Explore the Merchant Navy Decoded App, where seafarers can access MND FLIX technical learning resources, MMD exam preparation support, DG Shipping updates, and other useful maritime services.

Explore the Merchant Navy Decoded App

Types of Directional Control Valve

Valves can be identified in a few ways:-

  • Number of ports/ways: A 2 way valve will have 2 ports. They are essentially on/off. A 3 way valve will have 3 ports. An example would be to operate a single acting cylinder. A 4 way valve will have 4 main ports (P,T,A,B). These are the standard to use on double acting cylinders/motors.
  • Number of positions: A 2 position valve will have 2 spool positions. A 3 position valve will have an extra centre position. These are written together. A 4/3 valve will have 4 ports and 3 positions. A 4/2 will have 4 ports and 2 positions. A 3/2 will have 3 ports and 2 positions.
  • Centre position: This can be very important on 3 position valves. Common centre positions include:-
  1. Closed centre – All ports are blocked. The cylinder will be held in place and oil from the pump will need to be redirected somewhere else, for example over a relief valve or into an unloading circuit.
  2. Open centre – All ports will be connected to the tank. Pump will unload into tank at low pressure and the actuator will be free to move.
  3. Tandem centre – P to T. A & B are blocked. Pump will unload and actuator will be held.
  4. Float centre – A & B to tank. P is blocked. Actuator can float freely. This is useful for manually moving a cylinder.
  • Operation: Valves can be manually operated by a lever, mechanically by a cam/plunger, electrically by a solenoid, hydraulically/pneumatically by a pilot pressure or combination. Solenoid valves are operated by an electric coil. They are normally the choice when using a control system or push button. Large valves will often have a small solenoid valve to provide a pilot pressure to move the main spool. These are known as pilot operated or two stage valves. Many will have a spring return to push the spool back into the centre/rest position when there is no signal.
  • Construction: Most are spool valves. These are good for having multiple ports and flexible flow paths. However there is always a small amount of internal leakage between the spool and the body. Poppet valves have a ball/cone that sits on a seat. They have a tight seal with minimal leakage. This makes them the choice for holding a load.

Table of Contents

Check Valves

The check valve is the simplest of the valves. It will allow free flow in one direction.Inside there is a ball/poppet that is held onto a seat by a light spring. When oil flows in the correct direction it pushes the poppet off the seat and compresses the spring. This allows free flow. The pressure required to lift the poppet is known as cracking pressure. When oil tries to flow in the wrong direction the pressure and spring force will push the poppet tightly onto the seat.

Uses:

  • Prevent oil backflow from the pump when turned off.
  • Hold pressure in an accumulator circuit.
  • Allow oil to bypass an item in one direction.
  • Prevent load from falling when the pump is switched off.

 

Pilot operated check valves have an extra pilot piston. They operate as a normal check valve in the correct direction, however when a pressure is applied to the pilot line it will push the poppet open. This allows flow in the restricted direction. This is used to hold a load (e.g hatch in the up position) and release on demand. Pilot operated check valves are the basis of many load holding systems.

Flow Control Valves

Flow control valves control how much oil flows to control the speed of the cylinder/motor. The simplest of these are throttle valves (or needle valves). They have an adjustable restriction. The more you open the valve, the more oil will pass through and the faster your actuator will move. Closing the valve will slow down the actuator.

Basic throttle valves have a limitation. The flow through a restriction depends on the pressure drop. If the load changes the speed will change. Pressure compensated flow control valves have an internal compensator to ensure the pressure drop remains constant. This ensures a constant flow regardless of load. This gives a constant speed for things like winches or cargo hatches:-

  • Meter-in – Restriction in the supply.
  • Meter-out – Restriction in the return. This offers better control against a runaway load.
  • Bleed-off – Some oil from the pump is bypassed to tank.
Flow Control Valves

Adjustable Flow with Check Valve

 Often you will want to control the speed in one direction only. A throttle check valve (one-way flow control valve) has a throttle valve and check valve in parallel.

The check valve will be closed meaning the oil must flow through the adjustable throttle valve. This will control the speed. In the opposite direction the check valve will be open and oil will freely flow past the throttle valve. This will give full speed to the actuator.

A typical use would be to have a slow smooth extension but quick retraction. They can be fitted in different orientations to give meter-in or meter-out control on extension or retraction. Check the arrow/symbol on the valve to see which direction the flow is controlled.

  1. Counterbalance Valve: This is a specialised valve for controlling a load that is prone to runaway due to gravity/inertia. This would be for example a cylinder with a heavy load to lower or a motor on a winch.

It has two components:-

  • A check valve for free flow into the actuator. 
  • A pilot assisted relief valve. 

The relief valve will block the oil from leaving the actuator on the load side until opened. This holds the load.

During lowering the load side oil will be trapped by the counterbalance valve. When you want to lower the actuator you will supply oil to the other side. This pressure will act as a pilot signal. The higher the pressure the more the relief valve will open. Oil will now be allowed to flow from the load side. This means the load can only move at the speed the oil is supplied, giving smooth controlled lowering. If the load tries to run away the pilot pressure will reduce, closing the valve slightly and slowing the load down. This is the counterbalance effect.

This will be set to a pressure slightly higher than the load itself. The pilot ratio (e.g 3:1) will tell you how much pilot pressure is required compared to the set pressure.

Counterbalance valves are used on deck cranes, hydraulic hoists, winches, stern ramps and any vertical/overhung load.

Counterbalance Valve vs Throttle Valve

These two can be confusing as they both can be used to slow down an actuator.

  • A throttle valve is simply a restriction. It will set a speed but has no knowledge of the load. If the load tries to run away (e.g heavy weight to lower) the throttle won’t stop it. This can cause the load to pull the actuator faster than oil is being supplied, causing cavitation, uncontrolled movement and risk of the load falling. It also can’t hold a load firmly against gravity as there will always be some leakage.
  • A counterbalance valve is for holding and controlling a load. It will block the oil from leaving the actuator. This will hold a suspended load. It will also open in proportion to the pilot pressure. This means the load can only move at the speed oil is being supplied to the other side. It can cope with an overrunning load.

To sum up, use a throttle valve to set a speed against a constant load. Use a counterbalance valve when the load can push the actuator (e.g lowering a heavy item) and you need to hold and control it.

Many circuits will use both. For example a crane may have a counterbalance valve on the hoist to hold and control the load but also a flow control valve to set a max speed.

Common Issues

  • Oil contamination – This is the main cause of issues with valves. It can cause sticking spools, worn seats and blockage of small orifices.
  • Sticking spools – Caused by contamination, varnish, faulty solenoid/return spring.
  • Leaky check valves – Contaminated seat or worn poppet. Causes load to drift.
  • Incorrect or changed settings – Counterbalance valve set too low (load will creep) or too high (will cause jerky/hard lowering).
  • Faulty solenoid – Burnt coil, damaged connector, no power.
  • Air/aerated oil – Spongy/noisy.
  • Hot oil – Causes the oil to thin and affect valve performance.
  • Leaking seals – Around valve body and connections.

Best Practice

  • Ensure oil is kept clean: Filters should be changed regularly and oil should be checked regularly.
  • Never change the settings on a relief/counterbalance valve: They are set to protect the load/system. Ensure you follow the correct procedure and use a gauge.
  • Always lower/hold the load before working on any hydraulic valve: Isolate and de-pressurise the circuit. Be careful of trapped pressure. The counterbalance valve can hold a load/pressure in the actuator even when the pump is off.
  • Ensure valves are fitted in the right orientation: Check the arrows on the check/throttle check valves.
  • Label the circuit diagram and keep it handy: Learn the symbols.
  • Never use a throttle valve to hold a suspended load.
  • Follow manufactures torque and fitting instructions for cartridge/ manifold valves.

Conclusion

Although hydraulic valves can look like little metal blocks they all have a specific function. Directional valves direct oil, check valves only allow flow in one direction, flow control valves set a speed, throttle check valves only allow flow in one direction and counterbalance valves hold and control a load that wants to run away. Knowing what each valve does and keeping the oil clean will make operating and fault finding on a hydraulic system on deck much more predictable.

Frequently Asked Questions (FAQs)

Directional control valve, pressure control valve, flow control valve, check valve and counterbalance valve.

P = Pressure supply from pump. T = Return to tank. A & B = Work ports connecting to the actuator.

4 ports and 3 positions.

Closed centre – All ports blocked. Open centre – All ports to tank. Tandem centre – Pump unloads and actuator held. Float centre – Actuator ports to tank.

Spring loaded ball/poppet. Will allow flow when pressure exceeds cracking pressure. Will seal in the opposite direction.

Holds a load by restricting flow in one direction. Can be released on demand by pilot pressure opening the poppet.

An adjustable throttle with a check valve in parallel. Restricts flow in one direction.

A throttle is just a restriction. It can’t hold or control an overrunning load. A counterbalance valve can hold the load and only allow it to lower at the speed oil is supplied.

Ratio between pilot pressure required and pressure set on the valve. E.g 3:1.

Contaminated oil. Can cause sticking spools, worn seats and orifices.

Disclaimer :- The opinions expressed in this article belong solely to the author and may not necessarily reflect those of Merchant Navy Decoded. We cannot guarantee the accuracy of the information provided and disclaim any responsibility for it. Data and visuals used are sourced from publicly available information and may not be authenticated by any regulatory body. Reviews and comments appearing on our blogs represent the opinions of individuals and do not necessarily reflect the views of Merchant Navy Decoded. We are not responsible for any loss or damage resulting from reliance on these reviews or comments.

Reproduction, copying, sharing, or use of the article or images in any form is strictly prohibited without prior permission from both the author and Merchant Navy Decoded.

DIWALI SALE

Decoded Discount Alert! up to 50% OFF

DIWALI SALE

Decoded Discount Alert! up to 50% OFF

Use Coupon Code Deep50

Days
Hours
Seconds
0
Would love your thoughts, please comment.x
()
x