Electrical Distribution Group Starter Panel on Ship

Electrical Distribution

All equipment on board uses electricity, this includes pumps, fans, lights, winches and radars. There is no national grid, so the power is generated, distributed, protected and maintained in a fail-safe way. This is known as the electrical distribution system. Once you can follow the flow of electricity from the generator to the lamp inside the cabin, most of the equipment within the electrical department begins to make sense.

Want to learn more about group starter panels and their role in shipboard electrical distribution? Explore the Group Starter Panel Course by Merchant Navy Decoded to understand its components, working principles, motor control, and electrical protection systems onboard ships.

Overview

There are a few stages to electrical distribution:-

  1. Generation: Using diesel (turbine/shaft) generators electricity is generated.
  2. Main switchboard: This is where all the generators feed into. Electricity is controlled, distributed and protected.
  3. Feeders: The electricity is sent out to the motor starters, distribution boards and transformers.
  4. Transformers: This will reduce the supply for lights and smaller equipment.
  5. Emergency: An independent supply to ensure that there is still electricity in the event of a loss of main supply.

This is shown in a single line diagram.

Voltage and Frequency

Voltage and Frequency

Most ships will have a 3-phase voltage. The most common voltages used are 440V @ 60Hz, but some ships will have 380V or 400V @ 50Hz. The electricity is supplied at a high voltage and is reduced using a transformer to provide a low voltage supply to lights and small equipment. This is usually 220V (or 230V). There is also a 24V DC supply which comes from batteries and chargers. This is used for control circuits, alarms, emergency lighting and communications.

Large ships (tankers, cruise ships and some container ships) will have a high voltage supply. Usually this is 3.3kV, 6.6kV or 11kV. This reduces the current and therefore the size of cable needed. This high voltage will be stepped down using transformers to give 440V to normal equipment. Any high voltage equipment requires specialist training, procedures and safety equipment.

Table of Contents

Generators

Ships usually have several generators. This is so that if one needs to be maintained there will not be a blackout. It also means that there can be enough generators running to match the load. Depending on where the ship is, there may only be 1 or 2 generators running. When in port or using thrusters to manoeuvre there may be 3 or more generators running.

The generators will be synchronised and run in parallel. Before connecting the generators to the live bus, they must match the voltage, frequency and phase. This means that the generators share the load. This is achieved using governors and power management. No one generator will receive too much load.

Some ships will have a shaft generator. This is driven by the main engine and provides a low cost supply when at sea. Shore connection allows the ship to take power from the port. This means that the generators can be switched off.

Main Switchboard

The main switchboard is the core of the system. It contains:-

  • Busbars : Heavy copper bars which provide the whole of the supply. The generators feed into these and the feeders send power out. Many switchboards are split into sections with a bus-tie breaker between them. This will ensure that if there is a fault in one section of the board it will not affect the whole board.
  • Generator breakers: Large air circuit breakers (ACB). These connect the generators to the busbars.
  • Feeder breakers: These connect to the outgoing circuits.
  • Instruments and controls: Voltmeters, ammeters, frequency meters, synchroscope, kW meters and controls to start, stop and synchronise the generators.
  • Protection relays: These will detect any abnormal conditions and trip the correct breaker.
  • Insulation monitoring: As seen in the low insulation alarm post.

Protection

Protection is an important feature of the system. If there was a fault on the electrical system on the ship it could cause a fire or even a blackout when it is most needed. The main devices to protect the system are:-

  • Overcurrent/Short Circuit Protection: All circuits have overcurrent protection. If too much current flows through the circuit, the breaker or fuse will trip.
  • Overload Protection: Protection for motors so they don’t burn out.
  • Reverse Power Protection: If a generator begins to motor, the relay will trip.
  • Under Voltage: If voltage drops the breaker will trip.
  • Over Voltage, Over/Under Frequency: Protection for generators.
  • Preferential Tripping: If the generators are near overload, the system will automatically trip non-essential equipment such as air conditioning, galley equipment and some cooling pumps. This is a large reason why ships can often continue sailing in the event of a generator failure.
  • Selectivity (Discrimination): Breakers are set so that the breaker nearest to the fault will trip. This will not affect the other breakers. For example if there was a fault in a socket in a cabin, this should not trip the main breaker.

Distribution Boards and Motor Starters

From the main switchboard, feeders (large cables) will send power to:-

  1. Group starter panels or motor control centres: These contain the motor starters for pumps and fans. Each starter will contain a contactor, overload protection and often a local stop button.
  2. Large consumers: These include the bow thruster, large compressors and main sea water pumps. These will have their own breakers/starters.
  3. Distribution boards: These will be for lights and small power. Usually fed from a transformer.
  4. Transformers: These will provide the 220V (or 230V) system. This will have its own distribution boards for cabin lights, galley, small equipment and sockets.

The system is generally radial. Feeders will leave the main switchboard. They will then branch off. Each item of equipment will generally only have one source. Important equipment such as the steering gear will have a dual supply from different sections of the board.

Insulated System

The e main 440V and 220V systems are usually insulated. No points are deliberately connected to the hull. If there was one earth fault it will not trip the supply. The equipment will still run whilst the fault is located. If there was a second fault on another phase this would cause a short circuit through the hull. Therefore insulation levels are constantly monitored.

Emergency System

This is an independent supply. This ensures that essential services are maintained in the event of a loss of power. This could be due to a fire or flooding in the engine room.

  • Emergency Generator: This is a diesel generator in its own space. Usually this will be above the highest continuous deck and outside of the machinery space. This will automatically start if there is a loss of main supply. The rules state that it must supply the emergency equipment within 45 seconds.
  • Emergency Switchboard: This is usually supplied from the main switchboard via the interconnector feeder. This will always be live. If there is a loss of main supply the emergency generator will start. The interconnector breaker will trip and the emergency breaker will close. In normal operation the emergency board will supply the emergency equipment from the main supply.
  • Transitional Emergency Supply: This is batteries to allow certain equipment to run until the emergency generator starts. This includes emergency lighting and alarms.
  • Emergency Equipment: This will include essential equipment such as the steering gear, emergency lighting, navigational lights and equipment, communications, fire pumps, fire detection/alarm and watertight doors.

The emergency generator and system will be regularly tested. This includes testing the automatic start. The emergency switchboard must always be ready.

Emergency System

Emergency System

This is an independent supply. This ensures that essential services are maintained in the event of a loss of power. This could be due to a fire or flooding in the engine room.

  • Emergency Generator: This is a diesel generator in its own space. Usually this will be above the highest continuous deck and outside of the machinery space. This will automatically start if there is a loss of main supply. The rules state that it must supply the emergency equipment within 45 seconds.
  • Emergency Switchboard: This is usually supplied from the main switchboard via the interconnector feeder. This will always be live. If there is a loss of main supply the emergency generator will start. The interconnector breaker will trip and the emergency breaker will close. In normal operation the emergency board will supply the emergency equipment from the main supply.
  • Transitional Emergency Supply: This is batteries to allow certain equipment to run until the emergency generator starts. This includes emergency lighting and alarms.
  • Emergency Equipment: This will include essential equipment such as the steering gear, emergency lighting, navigational lights and equipment, communications, fire pumps, fire detection/alarm and watertight doors.

The emergency generator and system will be regularly tested. This includes testing the automatic start. The emergency switchboard must always be ready.

Blackout

If there is a loss of main supply (blackout) the emergency generator will start. Most ships will have an automatic system which will start a standby generator. The breaker will close onto the dead busbar. Essential equipment will be restarted in sequence (sequential restart). This is to ensure that not everything tries to start at once. Once the main supply is stable the essential equipment will be restarted. This will include lube oil pumps, cooling water pumps and fuel pumps. The steering gear and other auxiliaries will then be restarted. Finally the main engine can be restarted.

Cables and Earthing

Cables on ships are flame retardant. They will be in cable trays and ducts. They will be correctly supported, away from heat and fluids. Essential equipment will be routed so that if there was a fire it will not lose both the main and standby supplies. All metal casings will be earthed to the ship’s hull. This is separate to the insulated system. This means that any exposed metal will be at the potential of the hull and is safe to touch.

Common Faults

  • Insulation faults: Due to dampness, dirt or damaged cables.
  • Loose connections: Hotspots on breakers, busbars and terminals.
  • Breaker tripped: Due to overload or faulty equipment.
  • Generator faults: Poor load sharing or inability to synchronise when running in parallel.
  • Emergency generator unable to start:  Flat batteries, fuel issue or faulty automatic.
  • Settings changed/bypassed: This defeats the protection.
  • Dirty/damp switchboards: Dust and salt causing tracking.

Best Practice

  • Know the single line diagram of your ship. Know what essential and non-essential loads are.
  • Regularly test the emergency generator and automatic start. Maintain the batteries.
  • Keep switchboards clean, dry and tight. Thermal imaging or checking for hotspots as part of planned maintenance.
  • Never bypass any protection or change any settings.
  • Always follow isolation, lock-off and permit procedures when doing any electrical work. Ensure everything is dead before touching.
  • Take low insulation alarms seriously. Clear them quickly.
  • Keep the preferential trip and blackout systems tested.

Conclusion

The electrical distribution system seems quite complex but the principles are simple. Generate, distribute, protect all the branches and have an independent emergency supply ready in case of a loss of supply. The generators feed into the main switchboard. Feeders will send the electricity to the starters and transformers. Protection will prevent faults from affecting the rest of the system. The emergency system will ensure that essential services are maintained. Once you can follow the flow of electricity on the single line diagram it becomes much easier to trace a fault or plan a job.

Frequently Asked Questions (FAQs)

Usually 440V 3-phase @ 60Hz. Some ships will run at 380V/400V @ 50Hz. 220V/230V for lights and small equipment. 24V DC for control and emergency systems. Large ships may run at high voltage such as 3.3kV, 6.6kV, 11kV.

So that one can be maintained or failed whilst maintaining the supply. It allows enough generators to run to match the load.

When the generators are close to overload non-essential equipment will be tripped automatically to maintain the essential services.

If a generator starts to motor (being driven by the bus) it will trip.

To provide emergency services in the event of a loss of supply. It will automatically start and must provide the emergency loads within 45 seconds.

Batteries provide certain equipment such as emergency lighting and alarms whilst the emergency generator starts.

This connects two sections of the switchboard. This will allow faults to be isolated on one section.

Emergency generator starts. The standby generator starts and closes onto the dead bus. Essential services are restarted in sequence.

Disclaimer :- The opinions expressed in this article belong solely to the author and may not necessarily reflect those of Merchant Navy Decoded. We cannot guarantee the accuracy of the information provided and disclaim any responsibility for it. Data and visuals used are sourced from publicly available information and may not be authenticated by any regulatory body. Reviews and comments appearing on our blogs represent the opinions of individuals and do not necessarily reflect the views of Merchant Navy Decoded. We are not responsible for any loss or damage resulting from reliance on these reviews or comments.

Reproduction, copying, sharing, or use of the article or images in any form is strictly prohibited without prior permission from both the author and Merchant Navy Decoded.

DIWALI SALE

Decoded Discount Alert! up to 50% OFF

DIWALI SALE

Decoded Discount Alert! up to 50% OFF

Use Coupon Code Deep50

Days
Hours
Seconds
0
Would love your thoughts, please comment.x
()
x